RENOPLAN SYSTEM ASIA 1

How can resilient and textile flooring be installed extremely fast?

With UZIN PE 414 Turbo, UZIN PE 280 and UZIN NC 162 Turbo.

Working and downtimes should be as short as possible when installing new floor covering. Time can be saved with Renoplan System Asia 1. Only 3 hours* after the application of UZIN NC 162 Turbo the floor covering can be installed. However not only the very fast drying and early installation of the floor covering is an advantage but also the extremely smooth and uniform surface appearance thanks to the new Level Plus Effect. In most cases grinding is redundant and a reduced consumption of adhesive is guaranteed.

* at 20 °C / 68 °F and 65 % relative humidity

<p>Step 1: If it is not a new subfloor remove the existing floor covering first. Sand/brush subfloor to remove flooring remnants and weakly bonded adhesive
residues. Thoroughly clean area with a strong industrial vacuum cleaner.
</p>

Step 1: If it is not a new subfloor remove the existing floor covering first. Sand/brush subfloor...

<p>Step 2: Before using UZIN PE 414 Turbo shake well the container and pour the content into a clean bucket. Apply a full even coat of UZIN PE 414 Turbo using the UZIN Nylon Fibre Roller to strengthen the subfloor that is not adequately sound or sanded. Avoid any pooling as otherwise the material will not cure or the cure will be extremely retarded.</p>

Step 2: Before using UZIN PE 414 Turbo shake well the container and pour the content into a clean...

<p>Step 3: Apply the super fast primer UZIN PE 280 onto the fully dried coat of UZIN PE 414 Turbo to create a rough surface. Apply the primer with a short-nap
lamb skin roller or alternatively with a UZIN nylon fibre roller uniformly, thin and over the whole substrate. Because of the quick drying of UZIN PE 280, the surface can be levelled already after approx. 45 minutes.</p>

Step 3: Apply the super fast primer UZIN PE 280 onto the fully dried coat of UZIN PE 414 Turbo to...

<p>Step 4: Mix the rapid levelling compound UZIN NC 162 Turbo with clear cold water. Use a powerful electric handheld mixer for mixing, e. g. the WOLFF agitator Power X 1300.</p>

Step 4: Mix the rapid levelling compound UZIN NC 162 Turbo with clear cold water. Use a powerful...

<p>Step 5: Apply the rapid levelling compound UZIN NC 162 Turbo directly onto the surface. The raking method can be used as an alternative to levelling.
The screed rake from the UZIN product offering is recommended for this purpose.</p>

Step 5: Apply the rapid levelling compound UZIN NC 162 Turbo directly onto the surface. The raking...

<p>Step 6: Now use the UZIN spike roller, adjusted to the
thickness of the levelling compound, for aeration.</p>

Step 6: Now use the UZIN spike roller, adjusted to the thickness of the levelling compound, for...

<p>Step 7: Apply either the dispersion adhesives UZIN KE 2000 S or FA 330 after 3 hours* using a suitable notched trowel.

* at 20 °C / 68 °F and 65 % relative humidity</p>

Step 7: Apply either the dispersion adhesives UZIN KE 2000 S or FA 330 after 3 hours* using a...

<p>Step 8: Install the resilient or textile floor covering and roll down once over the whole surface, e. g. using the WOLFF pressure roller.</p>

Step 8: Install the resilient or textile floor covering and roll down once over the whole surface,...